A Reassuring Solution The 4200 Series Audio Rescue Assistance System is an extension of the time proven Cornell 4100 Rescue Assistance System that has received wide industry acceptance. The 4200 includes voice communication which is initiated by simply depressing the call station button transmitting the signal to a central annunicator panel. A single pulse tone and a flashing light signals the caller that the alarm has been received. The central station can then talk to the caller. The caller need not take any other action to communicate with the central station, an important feature when a caller is under stress in an emergency situation.
Versatile, Dependable The central station operator on receiving a call station signal activates a zone button that illuminates both a flashing red LED and a green "voice" LED. By depressing and releasing the "talk" button, voice communication is established for as long as required. Upon completion, the appropriate zone button is depressed again however, the flashing red light continues. If more than one zone is signaling, the control station accepts the calls in the same manner. When the emergency is resolved, the central station operator pushes a reset button that restores the entire system to stand-by status. In the event of a wiring fault, each annunicator button is equipped with a yellow LED that will illuminate and an alarm that will sound identifying the area requiring service.
Vandal Proof We offer the optional 4201/V Vandal Proof call stations. This design offers heavy duty switches and speakers along with stainless steel plates and tamper-proof screws. The switches and speakers are water-resistant for exterior applications.
Signage A complete line of Rescue Assistance Signage is also available. These signs meet ADA specifications for Area of Rescue applications.
Annunciator Options |
A4204 |
4 |
11"H x 10"W |
10"H x 9"W x 3-1/2"D |
| A4208 |
8 |
11"H x 14"W |
10"H x 13"W x 3-1/2"D |
| A4212 |
12 |
11"H x 18"W |
10"H x 17"W x 3-1/2"D |
| A4216 |
16 |
20"H x 14"W |
19"H x 13"W x 3-1/2"D |
| A4220 |
20 |
20"H x 14"W |
19"H x 13"W x 3-1/2"D |
| A4224 |
24 |
20"H x 18"W |
19"H x 17"W x 3-1/2"D |
|
Call Station |
4201 |
Unlimited |
Two Gang Plate |
Two Gang Box |
|
4201/V |
Unlimited |
Two Gang Plate |
Two Gang Box |
|
Power Supply Options |
8224D |
Transformer 24 VDC |
Plug in Transformer |
|
B-5243 |
Battery Back-up/Power Supply 24 VDC 3 AMPS |
12"H x 16"W x 5"D |
Specifications The Cornell Annunciator Panel shall include one alternate action switch with two internal LED indicators for each zone. An audible alarm on the Annunciator Panel will emit a minimum sound level of 90db at 30cm. A yellow LED light for each zone will illuminate and the alarm will emit a repeating sound if any of the supervised lines are faulted. The panel shall be constructed of anodized aluminum with permanently silk-screened zone designations on the panel as well as a designation strip.
The Cornell Call Station, Model 4201, shall consist of one momentary switch with LED and one audible alarm device with a sound level minimum of 70db at 30cm. The station will be wall mounted on a stainless steel plate.
Wiring Requirements Wiring shall consist of 22 gauge (minimum) wire. Three conductors plus one shielded pair are required between each Call Station and the Annunciator Panel not to exceed 3000 feet.
Power wire shall be 18 gauge (minimum). Two conductors are required between Model 8224 D Transformer or B-5243 Battery Power Supply and the Annunciator Panel not to exceed 500 feet.
| Stand by Mode |
No Light/Tone |
No Light/Tone |
| Alarm Sent |
Steady Red LED/Intermittent Tone |
Lighted Button/One time Tone |
| Alarm Acknowledged/Activated |
Flashing Red LED/Steady Green |
Flashing Button/One Time Tone |
| Intercom On |
Push to talk/Release to Listen |
Hands Free Communication |
| Intercom Off |
Flashing Red LED/Access Zone Button |
Flashing Button |
| Wiring Fault |
Yellow LED at Zone/Intermittent Tone |
Button will not light | |